Compressed Air Filtration

Line
Filters

Compressed air, after being compressed, carries oil aerosols, water droplets, and particulate matter that contaminate and corrode critical components. Lenora line filters deliver clean, contaminant-free air — in four grades, sized for any compressed air system.

Request a Quote → View Filter Grades
Lenora compressed air line filters — full range

The Problem

Compressed Air Is Never Clean at the Compressor Outlet

Every compressor introduces contamination into the air stream — oil carryover from lubricated compressors, water vapour that condenses downstream, rust and pipe scale from aging distribution systems, and atmospheric dust drawn in through the inlet.

Left untreated, these contaminants degrade pneumatic tools, clog instruments, contaminate food and pharma processes, and ruin paint finishes — causing expensive downtime and rework.

The Lenora Solution

Multi-Grade Filtration for Every Contamination Level

Lenora line filters are available in particulate, coalescing, and activated carbon grades — installed in sequence to progressively clean the air stream to the purity level your application demands.

"The right filter grade at the right point in the system is the foundation of a reliable compressed air installation."
Filter Grades

The Right Grade
for Every Stage

LP Series
Particulate
Filtration

Borosilicate glass fiber media. Removes dust, dirt, rust, pipe scale, and solid particles from the air stream. First line of defence — installed immediately after the compressor or aftercooler.

Media: Borosilicate Glass Fiber
LA Series
Coalescing
Filtration

Borosilicate glass fiber media with over 95% void volume. Most effective separation of water and oil — coalesces fine aerosols into droplets that drain away. Protects instruments, dryers, and precision equipment.

Media: Borosilicate Glass Fiber
LC Series
Activated
Carbon

Composite activated carbon media removes gases and hydrocarbon odours from the air stream — essential for food processing, pharmaceutical, and paint booth applications where odour-free air is critical.

Media: Activated Carbon Composite
LM Series
Oil Vapour
Removal

Borosilicate glass fiber media designed specifically to reduce oil vapour concentration — used in both oil-free and oil-lubricated compressor systems where oil vapour contamination must be minimised.

Media: Borosilicate Glass Fiber
Salient Features

Built to Last.
Easy to Service.

01
Non-Corrosive Aluminium Body

Lightweight aluminium housing resists corrosion in industrial environments. Compact and easy to mount in any orientation on the compressed air line.

02
High Efficiency, Low Pressure Drop

Borosilicate glass fiber media delivers over 95% void volume — large filtration area with high filter efficiency and very low pressure drop across the element.

03
Differential Pressure Gauge

Integrated DP gauge indicates when the cartridge needs replacement — no guesswork, no scheduled downtime, no missed change intervals.

04
Float Type Auto Drain (Optional)

Optional float-type auto drain valve removes collected liquid automatically — pair with a Lenora LADV for fully hands-free condensate management.

Compact Size Light Weight Zero Maintenance Easy to Operate BSP Connections Max 16 Bar
Lenora compressed air line filter — housing and element
Model Range

Sized for
Every System

Available in five flow capacities — 20, 40, 80, 125, and 200 CFM — across all four filter grades. Maximum working pressure: 16 Bar across the entire range.

Model Grade Flow (CFM) Port Size Max Pressure Dim A (mm) Dim B (mm)
LP 20Particulate201/2"16 Bar75272
LA 20Coalescing201/2"16 Bar75272
LC 20Activated Carbon201/2"16 Bar75272
LM 20Oil Vapour201/2"16 Bar75272
LP 40Particulate401/2"16 Bar86305
LA 40Coalescing401/2"16 Bar86305
LC 40Activated Carbon401/2"16 Bar86305
LM 40Oil Vapour401/2"16 Bar86305
LP 80Particulate803/4"16 Bar86305
LA 80Coalescing803/4"16 Bar86305
LC 80Activated Carbon803/4"16 Bar86305
LM 80Oil Vapour803/4"16 Bar86305
LP 125Particulate1251"16 Bar135452
LA 125Coalescing1251"16 Bar135452
LC 125Activated Carbon1251"16 Bar135452
LM 125Oil Vapour1251"16 Bar135452
LP 200Particulate2001 1/2"16 Bar135452
LA 200Coalescing2001 1/2"16 Bar135452
LC 200Activated Carbon2001 1/2"16 Bar135452
LM 200Oil Vapour2001 1/2"16 Bar135452
System Integration

Where to Install

After Compressor / Aftercooler Before Desiccant Dryer After Desiccant Dryer Before Precision Instruments Before Paint Booths Before Food & Pharma Processes At Each Point of Use Before Pneumatic Tools
Applications

Every Industry
Needs Clean
Air

Wherever compressed air touches a process or a product, filtration is not optional — it is the difference between a reliable system and one that fails when it cannot afford to.

Discuss Your Requirements →
Lenora filter element grades — full range
Hospitals Pharma Companies Food Processing Instrumentation Paint Booth Textile Mills Chemical Industries Rice Mills Automotive General Manufacturing
Related Products

Complete Your
Air Treatment Train

Need Filters Sized
for Your System?

Get in Touch →